Specifications
Area Coverage
A single coat is usually sufficient. Very porous surfaces should be treated first with an Epoxy Primer. Coverage area is approximately 18m² per 4.5L per coat. One coat is normally sufficient.
Fast Curing
Richco Chemical Coating will cure overnight to accept light usage the next day. Full chemical resistance is achieved over five to seven days.
Surface Preparation
Concrete and brick: Concrete to be treated must be dry, at least
four weeks old and free of any soft surface
laitance, contaminants, and not subject to
rising damp. All loose material should be
removed. Very smooth bare concrete or
concrete with soft surface laitance should
be etched. Grease or oil should be removed with
a degreasant and
the area thoroughly hosed off and allowed
to dry. Very smooth previously painted
surfaces should be abraded to
improve adhesion.
Steel:
Remove loose or flaking material, rust and
any previous coatings by wire brushing or
disc grinding to achieve a bright surface. Oil
or grease should be removed with a degreasant and the metal then washed with
Water and allowed to dry. Coating should
be carried out immediately providing flash
rusting has not occurred.
Mixing
The curing agent and resin must be very thoroughly mixed together with a wide bladed tool until an even colour is obtained.
Application
Best results are obtained in warm conditions (minimum 15°C). On horizontal surfaces apply by medium pile type roller in one coat. On vertical surfaces two thin coats are recommended. The second coat should be applied within 24 hours.
Application Tools
Apply Richco Chemical Coating using a medium pile type roller. Mix product with a wide bladed tool.
Cleaning of Application Tools
It is not practical to clean applicators and they should be discarded after use.